Mimo<Mimo>
RepCap Settings
# Range: Nr1 .. Nr8
rc = driver.wlanMeas.multiEval.trace.tsMask.mask.mimo.repcap_mimo_get()
driver.wlanMeas.multiEval.trace.tsMask.mask.mimo.repcap_mimo_set(repcap.Mimo.Nr1)
SCPI Commands :
READ:WLAN:MEASurement<Instance>:MEValuation:TRACe:TSMask:MASK:MIMO<n>
FETCh:WLAN:MEASurement<Instance>:MEValuation:TRACe:TSMask:MASK:MIMO<n>
- class MimoCls[source]
Mimo commands group definition. 4 total commands, 1 Subgroups, 2 group commands Repeated Capability: Mimo, default value after init: Mimo.Nr1
- fetch(start: float = None, count: float = None, decimation: float = None, mimo=Mimo.Default) List[float][source]
# SCPI: FETCh:WLAN:MEASurement<Instance>:MEValuation:TRACe:TSMask:MASK:MIMO<n> value: List[float] = driver.wlanMeas.multiEval.trace.tsMask.mask.mimo.fetch(start = 1.0, count = 1.0, decimation = 1.0, mimo = repcap.Mimo.Default)
Return the power values (Y-values) of the transmit spectrum mask limit line trace, for MIMO measurements, antenna <n>, bandwidths with one segment.
Suppressed linked return values: reliability
- param start:
For the optional query parameters start, count and decimation, see ‘Trace subarrays’.
- param count:
For the optional query parameters start, count and decimation, see ‘Trace subarrays’.
- param decimation:
For the optional query parameters start, count and decimation, see ‘Trace subarrays’.
- param mimo:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mimo’)
- return:
spec_trace_mask_tx: Comma-separated list of power values, trace from left to right
- read(start: float = None, count: float = None, decimation: float = None, mimo=Mimo.Default) List[float][source]
# SCPI: READ:WLAN:MEASurement<Instance>:MEValuation:TRACe:TSMask:MASK:MIMO<n> value: List[float] = driver.wlanMeas.multiEval.trace.tsMask.mask.mimo.read(start = 1.0, count = 1.0, decimation = 1.0, mimo = repcap.Mimo.Default)
Return the power values (Y-values) of the transmit spectrum mask limit line trace, for MIMO measurements, antenna <n>, bandwidths with one segment.
Suppressed linked return values: reliability
- param start:
For the optional query parameters start, count and decimation, see ‘Trace subarrays’.
- param count:
For the optional query parameters start, count and decimation, see ‘Trace subarrays’.
- param decimation:
For the optional query parameters start, count and decimation, see ‘Trace subarrays’.
- param mimo:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mimo’)
- return:
spec_trace_mask_tx: Comma-separated list of power values, trace from left to right
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.wlanMeas.multiEval.trace.tsMask.mask.mimo.clone()
Subgroups